© DENTAURUM GmbH & Co. KG
Dentaurum Home
Online-Shop
select your language
deutsch
english
français
español
italiano
Suchwort
Home
>
Orthodontics
>
Products
>
tomas® Anchorage System
>
Procedure
> Insertion preparation
Implantology
News
Products
tioLogic©
Tiolox®
Bone augmentation material
Field of work
Surgery
Prosthetic
Service
Customer Support Implantology
Knowledge
Press service
Orthodontics
News
Products
tomas® Anchorage System
Bracket systems
magic® Lingual System
Buccal Tubes
Bands
Adhesives
Wires and Arches
Intra- and Extraoral
Class II appliances
Supplies
Expansion Screws
Orthodontic Acrylics
Pliers
Equipment
Field of work
Precautions / early treatment / protective equipment
Impressions and model production
Treatment with anchorage systems
Multi band treatment
Class II appliances
Palatal expansion
Removable and functional orthodontic appliances
Service
Customer Support Orthodontics
Knowledge
Press service
Prosthetics
News
Products
Ceramics
Crowns and bridges
Combined prosthetics
Cast partial denture
Titanium
Finishing Tools
Equipment
Field of work
Work preparation
Wax technique / Sculpting
Investing
Casting and pre-heating
Sandblasting and extraction
Welding and soldering
Surface conditioning
Ceramics
Service
Customer Support dental laboratory
Knowledge
Press service
Service
Hotlines / Contact
Order service
Customer Support Implantology
Customer support Orthodontics
Customer support dental laboratory
Security data sheets, law for medical products
Training courses
Press
Implantological Knowledge
tioLogic© Surgical Manual
tioLogic© Prosthetic Manual
tioLogic© Implant System CD-ROM
Visual Library Implantology Live
Orthodontic Knowledge
Dynamics of Orthodontics
tomas® Anchorage system Illustrated atlas
tomas® Anchorage system CD-ROM
Practice handbook mini implants
Wire manual
o-atlas guide for removable restorations
SUS2 Sabbagh Universal Spring CD-ROM
Orthocryl® live CD-ROM
Instruction on preparing pliers and instruments
Knowledge on dental technology
remanium® kompendium chapter 1
remanium® kompendium chapter 2
remanium® kompendium chapter 3
CD-ROM
SUS² - Sabbagh Universal Spring CD-ROM
Orthocryl® CD-ROM
tioLogic© - Implant System CD-ROM
tomas® Anchorage system
Press service
News Implantology
News Orthodontics
News Prosthetics
News Courses
News Company
Press contact
Media library
Orthodontics
SUS² - Class II appliances
tomas® Anchorage System
Orthocryl® Acrylic system
Prosthetics
Crowns and bridges
Cast partial denture
Historical Movies
Downloads
Download-Center
Implantology
Catalog
Instructions for use
Patient information
Product information
Publications
Orthodontics
Catalog
Instructions for use
Patient information
Publications
Safety data sheets
Material list of orthodontic products
Prosthetics
Catalog
Instructions for use
Publications
Safety data sheets
Certifications
Courses
News
Course offers
Implantology
Orthodontics
CDC-Center for Dental Communication
Interior view
Course laboratories
The dental unit
Seminar rooms
Location Map
Service
Hotline
Registration
Press service
Company
News
Company profile
Company philosophy
Dental technology
Production paths
Facts
Gallery
Certifications
Company history
The founder
The origin of Dentaurum
Turbulent times for Dentaurum
The path to the world dental company
Setting course for the future
The future of Dentaurum
Arnold Biber Prize
Award winner
Location
Headquarters
National Organisations
International Distributors
Location Map
Hotlines / Contact
Order service
Customer Support Implantology
Customer support Orthodontics
Customer support dental laboratory
Security data sheets, law for medical products
Training courses
Press
Congresses & Exhibitions
Germany
International
Career
Job offers
Press
Press archive
Press contact
Legal information
Legal advice
Terms of Delivery and Payment
Imprint
News
Products (show all)
tomas® Anchorage System (show all)
Procedure
Preoperative planning
Insertion preparation
Site preparation
Insertion
Connection
Removal
Field of work
Service
Insertion preparation
Anesthesia
In the interradicular insertion of the tomas® pin the sensitivity of the periodont of the neighboring teeth should be maintained. For this reason the mucosa is anesthetized only superficially at the insertion point. For this purpose one can use surface anesthetics in gel form applied around 10 minutes before the insertion. A further possibility is local infiltration anesthesia.
Measurement of gingiva thickness
One measures the thickness of the gingiva at the insertion site with a pointed probe and a plugged on rubber ring. This information is required for the final determination of the screw length and when screwing in the tomas® pins.
Verification of insertion site
The insertion site is determined during treatment planning using radiographs, models and clinical findings. The insertion site can be easily and accurately marked using the tomas®-X marker.
Service telephone:
+49 (0) 7231/803-550
Media library tomas
®
tomas
®
Insertion Manual
Preoperative planning
Insertion preparation
Site preparation
Insertion
Connection
Removal
To the top of page